Tibiofemoral contact pressures in radial tears of the meniscus treated with all-inside repair, inside-out repair and partial meniscectomy

期刊

KNEE
卷 22, 期 5, 页码 400-404

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.knee.2015.05.008

关键词

Radial meniscus tear; All-inside repair; Inside-out repair; Biomechanical analysis; NovoStitch suture passer

资金

  1. Ceterix Orthopaedics Inc.

向作者/读者索取更多资源

Background: To test contact pressures in the knee after treatment of a radial meniscus tear with an all-inside meniscal repair technique and compare the results with inside-out repair and partial meniscectomy. Methods: Six non-paired cadaveric knees were analyzed with intra-compartment pressures measured at loads of 250 N, 500 N and 1000 N at 0 degrees, eight degrees, 15 degrees, and 30 degrees of knee flexion. Compartmental contact pressures were measured for the intact medial meniscus, radial tear in the posterior horn, all-inside repair using the NovoStitch suture passer device (Ceterix Orthopaedics Inc., Menlo Park, CA), inside-out repair method, and partial meniscectomy. One-way ANOVA was used for statistical analysis. Results: The greatest differences in peak pressures between treatments were observed under 1000 N load at 30 degrees flexion (0.8 +/- (SD) 0.1 MPa (intact meniscus), 0.8 +/- (SD) 0.1 MPa (all-inside), 0.9 +/- (SD) 0.1 MPa (inside-out) and 1.6 +/- (SD) 0.2 MPa (partial meniscectomy)). Treatment with partial meniscectomy resulted in the highest peak pressures compared to all other states (p < 0.0001 at each angle). Repair of the radial tear using the all-inside technique as well as the inside-out technique resulted in significantly decreased compartment pressures compared to partial meniscectomies (p < 0.0001 at each angle). There were no significant differences between peak pressures in the intact state and after repair with the all-inside or inside-out techniques. Conclusion: An all-inside repair technique using the NovoStitch suture passer can decrease contact pressures for a radial meniscus tear similarly to the inside-out repair technique when compared to partial meniscectomy. Clinical relevance: This novel arthroscopic suture passer warrants further analysis in the clinical setting as it may be a reliable method for repair of radial meniscal tears through an arthroscopic all-inside technique. (C) 2015 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据