期刊
FUEL
卷 103, 期 -, 页码 579-584出版社
ELSEVIER SCI LTD
DOI: 10.1016/j.fuel.2012.08.006
关键词
Hydrotreating; Waste cooking oil; Co-processing; Heavy gas oil; Diesel
资金
- European Commission
- Greek Government [SustainDiesel-09SYN-32-328]
The effect of temperature on hydrotreating of heavy gas oil (HGO)-waste cooking oil (WCO) mixtures was studied. Three different types of feedstock were studied, 100% HGO, 90/10 HGO/WCO and 70/30 HGO/WCO. Temperature is the most dominant operating parameter which defines catalyst performance as well as catalyst life. In this analysis, a hydrotreating temperature range of 310-350 degrees C was explored via a series of three experiments (310 degrees C, 330 degrees C and 350 degrees C). Several parameters were considered for evaluating the effect of temperature including heteroatom removal, conversion, pour point, hydrogen consumption and saturation of double bonds. For all experiments the same commercial hydrotreating catalyst was utilized (NiMo/Al2O3), while the remaining operating parameters were kept constant (pressure = 1200 psig, LHSV = 1.0 h(-1), H-2/Oil ratio = 505.9 nl/l, liquid feed = 40 ml/h, and gas feed = 21804 ml/h). (C) 2012 Elsevier Ltd. All rights reserved.