4.3 Article

Rapid Measurement and Prediction of Bacterial Contamination in Milk Using an Oxygen Electrode

期刊

FOODBORNE PATHOGENS AND DISEASE
卷 6, 期 2, 页码 187-192

出版社

MARY ANN LIEBERT, INC
DOI: 10.1089/fpd.2008.0174

关键词

-

资金

  1. MEXT

向作者/读者索取更多资源

An oxygen electrode was used to measure oxygen consumption to determine bacterial contamination in milk. Dissolved oxygen (DO) measured at 10-35 degrees C for 2 hours provided a reasonable prediction efficiency (r >= 0.90) of the amount of bacteria between 1.9 and 7.3 log (CFU/mL). A temperature-dependent predictive model was developed that has the same prediction accuracy like the normal predictive model. The analysis performed with and without stirring provided the same prediction efficiency, with correlation coefficient of 0.90. The measurement of DO is a simple and rapid method for the determination of bacteria in milk.