4.4 Article

An LC-ESI-MS/MS method for residues of fluoroquinolones, sulfonamides, tetracyclines and trimethoprim in feedingstuffs: validation and surveillance

出版社

TAYLOR & FRANCIS LTD
DOI: 10.1080/19440049.2018.1508895

关键词

LC-MS; MS; antimicrobials; feedingstuffs; veterinary drug residues; fluoroquinolones; sulfonamides

资金

  1. CAPES
  2. National Council for Scientific and Technological Development (CNPq)

向作者/读者索取更多资源

An increasing concern about food safety has been observed over the years. The presence of drugs residues in food is one of the major subjects of research in food safety. Feedingstuffs can be responsible for carryover into the food chain of residues of several drugs. This paper describes the development, validation and application of a fast and simple method for analysis of 24 antibiotic residues in feedingstuffs for cattle, pigs and poultry. Analytes include compounds from different antimicrobials classes, such as sulfonamides (sulfadiazine, sulfamethazine, sulfamethoxazole, sulfaquinoxaline, sulfachlorpyridazine, sulfadoxine, sulfadimethoxine, sulfizoxazole, sulfamerazine and sulfathiazole), fluoroquinolones (ciprofloxacin, enrofloxacin, norfloxacin, danofloxacin, difloxacin, sarafloxacin, flumequine, nalidixic acid and oxolinic acid), tetracyclines (tetracycline, doxycycline, oxytetracycline and chlortetracycline) and trimethoprim. Samples were extracted with methanol:water (70:30) 0.1% formic acid, followed by clean-up steps using centrifugation, low-temperature purification (LTP) and ultracentrifugation. Instrumental analysis was performed using liquid chromatography coupled to tandem mass spectrometry. Chromatographic separation was achieved using a C18 column and a mobile phase composed of acetonitrile and water, both with 0.1% formic acid. Validation parameters such as limit of detection (LOD), limit of quantification (LOQ), selectivity, linearity, accuracy, precision, decision limit (CC) and detection capability (CC) were determined and meet the adopted criteria. LOD and LOQ were set to 30 and 75 mu g kg(-1), respectively. Inter-day precision were in the range from 4.0 to 11.1%, and linearity provides values of r(2) above 0.95 for all analytes. The optimised method was applied to the analysis of more than 1500 real samples within the period 2012-2017. Non-compliant results were discussed and classified in terms of analytes, feed types and target species. Multivariate analysis of the data was performed using principal component analysis.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据