期刊
FLOW MEASUREMENT AND INSTRUMENTATION
卷 37, 期 -, 页码 42-53出版社
ELSEVIER SCI LTD
DOI: 10.1016/j.flowmeasinst.2014.02.003
关键词
Coriolis meter; Gaseous fuel; Hydrogen meter; Time response; Transient flow
For steady flows, Coriolis flow meters accurately measure mass flow. To study the performance of Coriolis meters under transient flows, we measured the instantaneous and totalized flow determined by two Coriolis meters. The tests used a Transient Flow Facility (TFF) developed to generate transient flow, pressure, and temperature conditions similar to those that occur when a hydrogen powered vehicle is refueled. During simulated cascade fills, the TFF discharged 3 kg of helium in 3 min at flows between 10 g/s and 45 g/s through the Coriolis meters and the TFF's standard. The TFF's expanded uncertainty (95% confidence level) for totalized mass during this cascade fill was 0.45%. For the same simulated cascade fill, both Coriolis meters measured the instantaneous flow within the uncertainty of the TFF and measured totalized flow within the International Organization of Legal Metrology Recommendation 139 maximum permissible errors for meters in gaseous fuel dispensers (1.0%). Published by Elsevier Ltd.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据