相关参考文献
注意:仅列出部分参考文献,下载原文获取全部文献信息。Risk Factors for Early Revision After Primary Total Hip Arthroplasty in Medicare Patients
Kevin J. Bozic et al.
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH (2014)
In Vivo Monitoring of Implant Osseointegration in a Rabbit Model Using Acoustic Sound Analysis
Catherine Ruther et al.
JOURNAL OF ORTHOPAEDIC RESEARCH (2014)
Predictive outcomes of revision total hip replacement-A consecutive series of 1176 patients with a minimum 10-year follow-up
A. Philpott et al.
MATURITAS (2014)
Estimating Risk in Medicare Patients With THA: An Electronic Risk Calculator for Periprosthetic Joint Infection and Mortality
Kevin J. Bozic et al.
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH (2013)
Instrumented hip implants: Electric supply systems
Marco P. Soares dos Santos et al.
JOURNAL OF BIOMECHANICS (2013)
Power management architecture for smart hip prostheses comprising multiple energy harvesting systems
Nuno M. Silva et al.
SENSORS AND ACTUATORS A-PHYSICAL (2013)
Electrical Stimulation: A Novel Tool for Tissue Engineering
Richard Balint et al.
TISSUE ENGINEERING PART B-REVIEWS (2013)
DESIGN METHODOLOGY FOR THE DEVELOPMENT OF LONG-TERM HIP PROSTHESIS SURVIVAL
M. Soares dos Santos et al.
JOURNAL OF BIOMECHANICS (2012)
IN VIVO MEASUREMENTS OF THE FRICTION MOMENT IN TOTAL HIP JOINT PROSTHESES DURING WALKING
Philipp Damm et al.
JOURNAL OF BIOMECHANICS (2012)
Mechanotransduction in adipocytes
Naama Shoham et al.
JOURNAL OF BIOMECHANICS (2012)
A New Piezoelectric Actuator Induces Bone Formation In Vivo: A Preliminary Study
Joana Reis et al.
JOURNAL OF BIOMEDICINE AND BIOTECHNOLOGY (2012)
Implantable Sensor Technology: From Research to Clinical Practice
Eric H. Ledet et al.
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS (2012)
High-Tech Hip Implant for Wireless Temperature Measurements In Vivo
Georg Bergmann et al.
PLOS ONE (2012)
A Review of the Responses of Two- and Three-Dimensional Engineered Tissues to Electric Fields
Marie Hronik-Tupaj et al.
TISSUE ENGINEERING PART B-REVIEWS (2012)
A SoC for Pressure Balance Measurement Application in Total Knee Arthroplasty
Ke Zhao et al.
AASRI CONFERENCE ON COMPUTATIONAL INTELLIGENCE AND BIOINFORMATICS (2012)
Pathways of macrophage apoptosis within the interface membrane in aseptic loosening of prostheses
Fei Yang et al.
BIOMATERIALS (2011)
Patient-reported outcomes in the Swedish Hip Arthroplasty Register RESULTS OF A NATIONWIDE PROSPECTIVE OBSERVATIONAL STUDY
O. Rolfson et al.
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME (2011)
Revision rates after total joint replacement CUMULATIVE RESULTS FROM WORLDWIDE JOINT REGISTER DATASETS
G. Labek et al.
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME (2011)
Risk of Subsequent Revision after Primary and Revision Total Joint Arthroplasty
Kevin L. Ong et al.
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH (2010)
Piezoelectric actuator: Searching inspiration in nature for osteoblast stimulation
C. Frias et al.
COMPOSITES SCIENCE AND TECHNOLOGY (2010)
Polymeric piezoelectric actuator substrate for osteoblast mechanical stimulation
C. Frias et al.
JOURNAL OF BIOMECHANICS (2010)
A Prospective Study of 80,000 Total Joint and 5000 Anterior Cruciate Ligament Reconstruction Procedures in a Community-Based Registry in the United States
Elizabeth W. Paxton et al.
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME (2010)
Total hip joint prosthesis for in vivo measurement of forces and moments
Philipp Damm et al.
MEDICAL ENGINEERING & PHYSICS (2010)
Sensing methodology for in vivo stability evaluation of total hip and knee arthroplasty
Shiying Hao et al.
SENSORS AND ACTUATORS A-PHYSICAL (2010)
Risk of Revision for Infection in Primary Total Hip and Knee Arthroplasty in Patients With Rheumatoid Arthritis Compared With Osteoarthritis: A Prospective, Population-Based Study on 108,786 Hip and Knee Joint Arthroplasties From the Norwegian Arthroplasty Register
Johannes C. Schrama et al.
ARTHRITIS CARE & RESEARCH (2010)
Internal loads in the human tibia during gait
Tim Wehner et al.
CLINICAL BIOMECHANICS (2009)
Future Young Patient Demand for Primary and Revision Joint Replacement: National Projections from 2010 to 2030
Steven M. Kurtz et al.
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH (2009)
RF Coupling in a 433-MHz Biotelemetry System for an Artificial Hip
Manoja D. Weiss et al.
IEEE ANTENNAS AND WIRELESS PROPAGATION LETTERS (2009)
An activation circuit for battery-powered biomedical implantable systems
Raul Morais et al.
SENSORS AND ACTUATORS A-PHYSICAL (2009)
Integration of a wireless lock-in measurement of hip prosthesis vibrations for loosening detection
U. Marschner et al.
SENSORS AND ACTUATORS A-PHYSICAL (2009)
Fabrication of a strain sensor for bone implant failure detection based on piezoresistive doped nanocrystalline silicon
P. Alpuim et al.
JOURNAL OF NON-CRYSTALLINE SOLIDS (2008)
An implantable ZigBee ready telemetric platform for in vivo monitoring of physiological parameters
Pietro Valdastri et al.
SENSORS AND ACTUATORS A-PHYSICAL (2008)
Novel ultrasound read-out for a wireless implantable passive strain sensor (WIPSS)
F. Gattiker et al.
SENSORS AND ACTUATORS A-PHYSICAL (2008)
Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030
Steven Kurtz et al.
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME (2007)
Implantable 9-channel telemetry system for in vivo load measurements with orthopedic implants
Friedmar Graichen et al.
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING (2007)
Piezoelectric micro-power generation interface circuits
Triet T. Le et al.
IEEE JOURNAL OF SOLID-STATE CIRCUITS (2006)
Chronic, programmed polypeptide delivery from an implanted, multireservoir microchip device
JH Prescott et al.
NATURE BIOTECHNOLOGY (2006)
Three-dimensional dynamic hip contact area and pressure distribution during activities of daily living
H. Yoshida et al.
JOURNAL OF BIOMECHANICS (2006)
Correlation of radiographic and telemetric data from massive implant fixations
A. D. Shah et al.
JOURNAL OF BIOMECHANICS (2006)
Determination of muscle loading at the hip joint for use in pre-clinical testing
MO Heller et al.
JOURNAL OF BIOMECHANICS (2005)
On low-frequency electric power generation with PZT ceramics
SR Platt et al.
IEEE-ASME TRANSACTIONS ON MECHATRONICS (2005)
Tissue engineering of bone: effects of mechanical strain on osteoblastic cells in type I collagen matrices
A Ignatius et al.
BIOMATERIALS (2005)
Hip joint contact forces during stumbling
G Bergmann et al.
LANGENBECKS ARCHIVES OF SURGERY (2004)
Direct comparison of calculated hip joint contact forces with those measured using instrumented implants. An evaluation of a three-dimensional mathematical model of the lower limb
BW Stansfield et al.
JOURNAL OF BIOMECHANICS (2003)
How much can a vibrational diagnostic tool reveal in total hip arthroplasty loosening?
G Qi et al.
CLINICAL BIOMECHANICS (2003)
Nitric oxide synthase in tissues around failed hip prostheses
S Stea et al.
BIOMATERIALS (2002)
Mechanical strain and bone cell function: A review
PJ Ehrlich et al.
OSTEOPOROSIS INTERNATIONAL (2002)
Influence of femoral anteversion on proximal femoral loading: measurement and simulation in four patients
MO Heller et al.
CLINICAL BIOMECHANICS (2001)
Forces and moments telemetered from two distal femoral replacements during various activities
SJG Taylor et al.
JOURNAL OF BIOMECHANICS (2001)
Loads acting in an intramedullary nail during fracture healing in the human femur
E Schneider et al.
JOURNAL OF BIOMECHANICS (2001)
Hip contact forces and gait patterns from routine activities
G Bergmann et al.
JOURNAL OF BIOMECHANICS (2001)
Musculo-skeletal loading conditions at the hip during walking and stair climbing
MO Heller et al.
JOURNAL OF BIOMECHANICS (2001)
Frictional heating of total hip implants. Part 1. measurements in patients
G Bergmann et al.
JOURNAL OF BIOMECHANICS (2001)
A novel transducer for the measurement of cement-prosthesis interface forces in cemented orthopaedic devices
L Cristofolini et al.
MEDICAL ENGINEERING & PHYSICS (2000)
Concept, design and fabrication of smart orthopedic implants
F Burny et al.
MEDICAL ENGINEERING & PHYSICS (2000)
A telemetry system for the detection of hip prosthesis loosening by vibration analysis
R Puers et al.
SENSORS AND ACTUATORS A-PHYSICAL (2000)