4.6 Article

Detailed analysis of phase distributions in a vertical riser using wire mesh sensor (WMS)

期刊

EXPERIMENTAL THERMAL AND FLUID SCIENCE
卷 59, 期 -, 页码 32-42

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.expthermflusci.2014.07.010

关键词

Air-silicone oil; Air-water; WMS; Radial void fraction; Riser

资金

  1. Nigerian government through the Petroleum Technology Development Fund (PTDF)
  2. EPSRC [EP/E004644/1] Funding Source: UKRI
  3. Engineering and Physical Sciences Research Council [EP/E004644/1] Funding Source: researchfish

向作者/读者索取更多资源

This paper looks into the results of an experimental study concerned with the phase distributions of gasliquid multiphase flows experienced in a vertical riser. Scale experiments were carried out using a mixture of air and silicone oil in a 6 m long riser pipe with an internal diameter pipe of 67 mm. A series of pipe flow experiments were performed for a range of injected air superficial velocities over the range 0.05-4.73 m/s, whilst the liquid superficial velocities ranged from 0.05 to 0.38 m/s. Measurements of cross-sectional void fraction and radial time averaged void fraction across a pipe section located 4.92 m from the pipe flow injection were obtained using a capacitance wire mesh sensor (WMS). The data were recorded at a frequency of 1000 Hz over an interval of 60 s. For the range of flow conditions studied, the average void fraction was observed to vary between 0.1 and 0.83. An analysis of the data collected concluded that the observed void fraction was strongly affected by the gas superficial velocity, whereby the higher the gas superficial velocity, the higher was the observed average void fraction. The average void fraction distributions observed were in good agreement with the results obtained by other researchers. The accuracy and performance of void fraction correlations were carried out in terms of percentage error and Root Mean Square (RMS) error. Reasonably symmetric radial void fraction profiles were obtained when the air-silicone oil was fully developed, and the shape of the symmetry profile was strongly dependent on the gas superficial velocity. The data for air/water and air/silicone oil systems showed reasonably good agreement except at gas superficial velocity of 0.05 m/s. A comparison of the experimental data was performed against a published model to investigate the flow structure of airwater mixtures in a bubble column. A satisfactory report was observed for radial void fraction profile (mean relative error is within 5.7%) at the higher gas superficial velocities. (C) 2014 Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据