4.7 Article

The Choice of Hemodialysis Membrane Affects Bisphenol A Levels in Blood

期刊

JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY
卷 27, 期 5, 页码 1566-1574

出版社

AMER SOC NEPHROLOGY
DOI: 10.1681/ASN.2015030312

关键词

-

资金

  1. Programa Intensificacion Actividad Investigadora (ISCIII/Agencia Lain-Entralgo/CM)
  2. Nipro corporation
  3. Spanish government [PI13/00047, MS12/03262, CP10/00479, PI13/00802, PI14/00883]
  4. European Regional Development Fund (ERDF/FEDER) grants (ISCIII-RETIC RED) [REN/RD06/0016, RD12/0021]
  5. Comunidad de Madrid [S2010/BMD-2378]
  6. Spanish Nephology Society (SENEFRO)
  7. Fundacion Renal Inigo Alvarez de Toledo (FRIAT)

向作者/读者索取更多资源

Bisphenol A (BPA), a component of some dialysis membranes, accumulates in CKD. Observational studies have linked BPA exposure to kidney and cardiovascular injury in humans, and animal studies have described a causative link. Normal kidneys rapidly excrete BPA, but insufficient excretion may sensitize patients with CKD to adverse the effects of BPA. Using a crossover design, we studied the effect of dialysis with BPA-containing polysulfone or BPA-free polynephron dialyzers on BPA levels in 69 prevalent patients on hemodialysis: 28 patients started on polysulfone dialyzers and were switched to polynephron dialyzers; 41 patients started on polynephron dialyzers and were switched to polysulfone dialyzers. Results were grouped for analysis. Mean BPA levels increased after one hemodialysis session with polysulfone dialyzers but not with polynephron dialyzers. Chronic (3-month) use of polysulfone dialyzers did not significantly increase predialysis serum BPA levels, although a trend toward increase was detected (from 48.8 +/- 6.8 to 69.1 +/- 10.1 ng/ml). Chronic use of polynephron dialyzers reduced predialysis serum BPA (from 70.6 +/- 8.4 to 47.1 +/- 7.5 ng/ml, P<0.05). Intracellular BPA in PBMCs increased after chronic hemodialysis with polysulfone dialyzers (from 0.039 +/- 0.002 to 0.043 +/- 0.001 ng/10(6) cells, P<0.01), but decreased with polynephron dialyzers (from 0.045 +/- 0.001 to 0.036 +/- 0.001 ng/10(6) cells, P<0.01). Furthermore, chronic hemodialysis with polysulfone dialyzers increased oxidative stress in PBMCs and inflammatory marker concentrations in circulation. In vitro, polysulfone membranes released significantly more BPA into the culture medium and induced more cytokine production in cultured PBMCs than did polynephron membranes. In conclusion, dialyzer BPA content may contribute to BPA burden in patients on hemodialysis.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据