4.6 Article

Single-Port Laparoscopic and Robotic Partial Nephrectomy

期刊

EUROPEAN UROLOGY
卷 55, 期 5, 页码 1163-1169

出版社

ELSEVIER
DOI: 10.1016/j.eururo.2008.12.029

关键词

Laparoscopy; Nephron sparing; Single port

向作者/读者索取更多资源

Background: Partial nephrectomy (PN) for small renal masses provides effective oncologic outcomes. Single-port laparoscopic (SPL) and robotic surgeries are evolving approaches to advance minimally invasive surgery. Objective: To determine the feasibility of laparoscopic and robotic single-port PN. Design, setting, and participants: Since 2007, evaluation of patients undergoing SPL and single-port robotic (SPR) PN at a primary referral center was performed. Patients with small, solitary, exophytic-enhancing renal masses were selected. Patients with a solitary kidney, endophytic or hilar tumors, and previous abdominal and/or kidney surgery were excluded. Perioperative and pathologic data were entered prospectively into an institutional review board (IRB)-approved database. Interventions: Tumor location determined either an open Hasson transperitoneal or retroperitoneal approach. A single multichannel port or Triport provided intra-abdominal access. The Harmonic Scalpel was used for tumor excision under normal renal perfusion. The da Vinci surgical robot was used for SPR cases. Measurements: Patient demographics, perioperative, hematologic, and pathologic data as well as pain assessment using the Visual Analog Pain Scale (VAPS) were assessed. Results and limitations: A total of seven patients underwent single-port PN (SPL = 5, SPR = 2). One patient with a right anterior upper-pole mass required conversion from SPL to standard laparoscopy following tumor excision because of intraoperative bleeding. Pathology revealed six lesions compatible with renal cell carcinoma (RCC) and one benign cyst. One negative frozen section came back focally positive on final histopathology. All other surgical margins were negative. A mean difference of 3.0 +/- 2.0 g/dl in hemoglobin was noted in all patients. Minimal pain was noted at discharge following both laparoscopic and robotic single-port surgery (VAPS = 1.7 +/- 1.2 vs 1 +/- 0.5/10). Conclusions: SPL and SPR PN is feasible for select exophytic tumors. Robotics may improve surgical capabilities during single-port surgery. (C) 2009 European Association of Urology. Published by Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据