4.7 Article

Dual-energy CT lung ventilation/perfusion imaging for diagnosing pulmonary embolism

期刊

EUROPEAN RADIOLOGY
卷 23, 期 10, 页码 2666-2675

出版社

SPRINGER
DOI: 10.1007/s00330-013-2907-x

关键词

Dual energy; Tomography; X-ray computed; Lung ventilation; Lung perfusion; Pulmonary embolism

资金

  1. Bayer
  2. Bracco
  3. GE Healthcare
  4. Medrad
  5. Siemens
  6. Peak of Six Major Talents program of Jiangsu Province of China [WSW-122]
  7. Medical Major Talents program of Jiangsu Province of China [RC2011129]
  8. Program for New Century Excellent Talents in University [NCET-12-0260]

向作者/读者索取更多资源

To evaluate the feasibility and findings of combined dual-energy computed tomography (DECT) lung ventilation/perfusion imaging in patients with suspected pulmonary embolism (PE). This study was institutional review board-approved and written informed consent was obtained from each patient. Thirty-two subjects (aged 11-61 years) underwent combined xenon-enhanced ventilation and iodine-enhanced perfusion DECT. Ventilation, perfusion and morphological information were visually interpreted. Ventilation/perfusion information was classified as mismatch (differing patterns) or match (concordant patterns). Adverse reactions and radiation doses were recorded for each subject. Of 32 patients undergoing xenon-enhanced DECT, six patients reported adverse reactions (shortness of breath, n = 2; mild dizziness, n = 3; limb numbness, n = 1). Twenty-eight of 32 patients could be included into the data analysis. PE was detected in 10/28 patients. PE-related ventilation/perfusion mismatch was found in 17 lung lobes in 8/10 patients and matched ventilation/perfusion was detected in 2 patients. Eighteen patients had no PE. In this group, there was no case of a ventilation/perfusion mismatch. Matched ventilation/perfusion impairment was seen in one patient. The overall radiation dose from two DECT acquisitions was 4.8 +/- 1.4 mSv (range 2.7-7.5 mSv). DECT lung ventilation/perfusion imaging is feasible and can visualise ventilation/perfusion match or mismatch in patients with suspected PE. aEuro cent Combined dual-energy CT lung ventilation/perfusion imaging is feasible. aEuro cent Combined dual-energy CT ventilation/perfusion imaging provides lung morphological and functional information. aEuro cent Dual-energy CT can demonstrate ventilation/perfusion mismatch in patients with pulmonary embolism.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据