4.7 Article

Ultrasound-guided percutaneous release of the annular pulley in trigger digit

期刊

EUROPEAN RADIOLOGY
卷 19, 期 9, 页码 2232-2237

出版社

SPRINGER
DOI: 10.1007/s00330-009-1397-3

关键词

Trigger digit; Trigger finger; Ultrasound guided; Percutaneous release; Annular pulley; A1 pulley

向作者/读者索取更多资源

The purpose of this study was to describe and evaluate a new technique for ultrasound-guided percutaneous release of the annular pulley in trigger digit using a modified hypodermic needle. A total of 35 ultrasound-guided percutaneous releases were performed on 25 patients diagnosed and referred by hand surgeons in our institution over 16 months from October 2006. Inclusion criteria were as follows: adulthood, triggering present for at least 4 months, failure to respond to conservative management or steroid injections, no previous history of pulley release in the affected digit. Under ultrasound guidance, the affected pulley was released using a standard 19-gauge hypodermic needle bent at two points as the cutting device. Follow-up took place at 12 weeks and 6 months with improvement in triggering and clinically graded pain. At follow-up, no complications had occurred and all patients demonstrated improvement in their triggering, with complete resolution in 32 digits (91%), good improvement in 2 digits (6%) and some improvement in 1 digit (3%). This new technique uses a widely available and safe cutting device and is safe and can be used to provide definitive management for trigger finger, allowing the procedure to be performed in a variety of clinical settings.