4.5 Article

Optimizing chamber methods for measuring nitrous oxide emissions from plot-based agricultural experiments

期刊

EUROPEAN JOURNAL OF SOIL SCIENCE
卷 65, 期 2, 页码 295-307

出版社

WILEY
DOI: 10.1111/ejss.12117

关键词

-

资金

  1. UK Department for Environment, Food and Rural Affairs (Defra)
  2. Department of Agriculture and Rural Development in Northern Ireland
  3. Scottish Government
  4. Welsh Government
  5. Biotechnology and Biological Sciences Research Council [BB/K001051/1] Funding Source: researchfish
  6. BBSRC [BB/K001051/1] Funding Source: UKRI

向作者/读者索取更多资源

Nitrous oxide emissions (N2O) from agricultural land are spatially and temporally variable. Most emission measurements are made with small (MUCH LESS-THAN 1 m(2) area) static chambers. We used N2O chamber data collected from multiple field experiments across different geo-climatic zones in the UK and from a range of nitrogen treatments to quantify uncertainties associated with flux measurements. Data were analysed to assess the spatial variability of fluxes, the degree of linearity of headspace N2O accumulation and the robustness of using ambient air N2O concentrations as a surrogate for sampling immediately after closure (T-0). Data showed differences of up to more than 50-fold between the maximum and minimum N2O flux from five chambers within one plot on a single sampling occasion, and that reliability of flux measurements increased with greater numbers of chambers. In more than 90% of the 1970 cases where linearity of headspace N2O accumulation was measured (with four or more sampling points), linear accumulation was observed; however, where non-linear accumulation was seen this could result in a 26% under-estimate of the flux. Statistical analysis demonstrated that the use of ambient air as a surrogate for T-0 headspace samples did not result in any consistent bias in calculated fluxes. Spatial variability has the potential to result in erroneous flux estimates if not taken into account, and generally introduces a far larger uncertainty into the calculated flux (commonly orders of magnitude more) than any uncertainties introduced through reduced headspace sampling or assumption of linearity of headspace accumulation. Hence, when deploying finite resources, maximizing chamber numbers should be given priority over maximizing the number of headspace samplings per enclosure period.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据