4.5 Article

Intravoxel incoherent motion diffusion imaging of the liver: Optimal b-value subsampling and impact on parameter precision and reproducibility

期刊

EUROPEAN JOURNAL OF RADIOLOGY
卷 83, 期 12, 页码 2109-2113

出版社

ELSEVIER IRELAND LTD
DOI: 10.1016/j.ejrad.2014.09.003

关键词

Diffusion weighted imaging; b-Value; Perfusion; Pseudo-diffusion; Optimization; Liver; Intravoxel incoherent motion

资金

  1. NIDDK Grant [1R01DK087877]

向作者/读者索取更多资源

Purpose: To increase diffusion sampling efficiency in intravoxel incoherent motion (IVIM) diffusionweighted imaging (DWI) of the liver by reducing the number of diffusion weightings (b-values). Materials and methods: In this IRB approved HIPAA compliant prospective study, 53 subjects (M/F 38115, mean age 52 +/- 13 y) underwent IVIM DWI at 1ST using 16 b-values (0-800 s/mm(2)), with 14 subjects having repeat exams to assess IVIM parameter reproducibility. A biexponential diffusion model was used to quantify IVIM hepatic parameters (PF: perfusion fraction, D: true diffusion and D*: pseudo diffusion). All possible subsets of the 16 b-values were probed, with number of b values ranging from 4 to 15, and corresponding parameters were quantified for each subset. For each b-value subset, global parameter estimation error was computed against the parameters obtained with all 16 b-values and the subsets providing the lowest error were selected. Interscan estimation error was also evaluated between repeat exams to assess reproducibility of the IVIM technique in the liver. The optimal b-values distribution was selected such that the number of b-values was minimal while keeping parameter estimation error below interscan reproducibility error. Results: As the number of b-values decreased, the estimation error increased for all parameters, reflecting decreased precision of IVIM metrics. Using an optimal set of 4 b-values (0, 15, 150 and 800 s/mm(2)), the errors were 6.5, 22.8 and 66.1% for D, PF and D* respectively. These values lie within the range of test-retest reproducibility for the corresponding parameters, with errors of 12.0, 32.3 and 193.8% for D, PF and D* respectively. Conclusion: A set of 4 optimized b-values can be used to estimate IVIM parameters in the liver with significantly shorter acquisition time (up to 75%), without substantial degradation of IVIM parameter precision and reproducibility compared to the 16 b-value acquisition used as the reference. (C) 2014 Elsevier Ireland Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据