4.5 Article

Interobserver agreement of semi-automated and manual measurements of functional MRI metrics of treatment response in hepatocellular carcinoma

期刊

EUROPEAN JOURNAL OF RADIOLOGY
卷 83, 期 3, 页码 487-496

出版社

ELSEVIER IRELAND LTD
DOI: 10.1016/j.ejrad.2013.11.016

关键词

Response assessment; Reproducibility; Observer agreement; Functional magnetic resonance imaging; Cancer treatment response

资金

  1. Siemens Medical

向作者/读者索取更多资源

Purpose: To assess the interobserver agreement in 50 patients with hepatocellular carcinoma (HCC) before and 1 month after intra-arterial therapy (IAT) using two semi-automated methods and a manual approach for the following functional, volumetric and morphologic parameters: (1) apparent diffusion coefficient (ADC), (2) arterial phase enhancement (AE), (3) portal venous phase enhancement (VE), (4) tumor volume, and assessment according to (5) the Response Evaluation Criteria in Solid Tumors (RECIST), and (6) the European Association for the Study of the Liver (EASL). Materials and methods: This HIPAA-compliant retrospective study had institutional review board approval. The requirement for patient informed consent was waived. Tumor ADC, AE, VE, volume, RECIST, and EASL in 50 index lesions was measured by three observers. Interobserver reproducibility was evaluated using intraclass correlation coefficients (ICC). P < 0.05 was considered to indicate a significant difference. Results: Semi-automated volumetric measurements of functional parameters (ADC, AE, and VE) before and after IAT as well as change in tumor ADC, AE, or VE had better interobserver agreement (ICC = 0.830-0.974) compared with manual ROI-based axial measurements (ICC = 0.157-0.799). Semi-automated measurements of tumor volume and size in the axial plane before and after IAT had better interobserver agreement (ICC = 0.854-0.996) compared with manual size measurements (ICC = 0.543-0.596), and interobserver agreement for change in tumor RECIST size was also higher using semi-automated measurements (ICC = 0.655) compared with manual measurements (ICC = 0.169). EASL measurements of tumor enhancement in the axial plane before and after IAT ((ICC = 0.758-0.809), and changes in EASL after IAT (ICC = 0.653) had good interobserver agreement. Conclusion: Semi-automated measurements of functional changes assessed by ADC and VE based on whole-lesion segmentation demonstrated better reproducibility than ROI-based axial measurements, or RECIST or EASL measurements. (C) 2013 Elsevier Ireland Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据