4.5 Article

Quantification of left and right ventricular function and myocardial mass: Comparison of low-radiation dose 2nd generation dual-source CT and cardiac MRI

期刊

EUROPEAN JOURNAL OF RADIOLOGY
卷 81, 期 4, 页码 E598-E604

出版社

ELSEVIER IRELAND LTD
DOI: 10.1016/j.ejrad.2011.07.001

关键词

DSCT; Cardiac CT; Cardiac MRI; Myocardial mass; Cardiac function

资金

  1. Bayer-Schering
  2. Bracco
  3. General Electric
  4. Medrad
  5. Siemens

向作者/读者索取更多资源

Objective: To prospectively evaluate the accuracy of left and right ventricular function and myocardial mass measurements based on a dual-step, low radiation dose protocol with prospectively ECG-triggered 2nd generation dual-source CT (DSCT), using cardiac MRI (cMRI) as the reference standard. Materials and methods: Twenty patients underwent 1.5 T cMRI and prospectively ECG-triggered dual-step pulsing cardiac DSCT. This image acquisition mode performs low-radiation (20% tube current) imaging over the majority of the cardiac cycle and applies full radiation only during a single adjustable phase. Full-radiation-phase images were used to assess cardiac morphology, while low-radiation-phase images were used to measure left and right ventricular function and mass. Quantitative CT measurements based on contiguous multiphase short-axis reconstructions from the axial CT data were compared with short-axis SSFP cardiac cine MRI. Contours were manually traced around the ventricular borders for calculation of left and right ventricular end-diastolic volume, end-systolic volume, stroke volume, ejection fraction and myocardial mass for both modalities. Statistical methods included independent t-tests, the Mann-Whitney U test, Pearson correlation statistics, and Bland-Altman analysis. Results: All CT measurements of left and right ventricular function and mass correlated well with those from cMRI: for left/right end-diastolic volume r = 0.885/0.801, left/right end-systolic volume r = 0.947/0.879, left/right stroke volume r = 0.620/0.697, left/right ejection fraction r = 0.869/0.751, and left/right myocardial mass r = 0.959/0.702. Mean radiation dose was 6.2 +/- 1.8 mSv. Conclusions: Prospectively ECG-triggered, dual-step pulsing cardiac DSCT accurately quantifies left and right ventricular function and myocardial mass in comparison with cMRI with substantially lower radiation exposure than reported for traditional retrospective ECG-gating. (C) 2011 Elsevier Ireland Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据