Objectives: Protein binding and relaxivity are major determinants of the relative effectiveness of an MR arthrographic contrast agent. We sought to evaluate the optimal concentrations of high and usual relaxivity agents in two different proteinous environments at variable field strength for two MR contrast agents of different relaxivities. Materials and methods: At 1.5, 3.0 and 7.0 T, gadobenate dimeglumine (Multihance) with high-relaxivity in proteinous environment and gadoteridol (Prohance) with more typical behavior were studied at 1.25, 2.5, 5, and 10 mmol in 1.7 g/dL and 3 g/dL albumin (mimicking protein content of normal and inflammatory synovial fluids, respectively) vs. pure normal saline, as a control. Analysis of image signal intensity (SI) and relaxivity values was done. Results: In our study a change in concentration had no significant effect on T1 SI. In contrast, nearly every change in concentration led to a significant change in T2 SI. In 1.25 mmol concentration, there was no effect on T1 SI of either protein concentrations while higher concentrations showed significant decreased SI in either protein carrier compared to saline. The SI of Gadoteridol was significantly higher (p < 0.0001) than that of gadobenate at each of 3 T and 7 T, but was significantly lower (p < 0.001) at 1.5 T in saline solution while this was not significant for either protein carrier. Both protein carriers had significant effect on T1 (p = 0.0124) and T2 (p = 0.0118) relaxivities. Also solution concentration significantly (p < 0.01) affected both T1 and T2 relaxivities. Field strength did not affect T1 relaxivity (p = 0.02511) while it significantly affected T2 relaxivity (p < 0.001). This was significant (p = 0.035) in case of gadoteridol at 3 T. Conclusion: 1.25 mmol concentration of both gadoteridol and gadobenate solutions yields the best diagnostic T1 SI specially in higher fields ( 3 T and 7 T) and avoid the deleterious effect of increasing concentration on T2 SI. Gadoteridol is suggested on 3 T field indirect MR arthrograms. Protein had no positive effect on either SI or relaxivities in any joint model. (C) 2010 Elsevier Ireland Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据