4.6 Article

Evaluation of the suitability of chromatographic systems to predict human skin permeation of neutral. compounds

期刊

EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES
卷 50, 期 5, 页码 557-568

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.ejps.2013.04.005

关键词

Skin permeation prediction; High-performance liquid chromatography; Micellar electrokinetic chromatography; Octanol-water partition; Quantitative structure-activity relationships

资金

  1. Ministerio de Ciencia e Innovacion of the Spanish Government
  2. Fondo Europeo de Desarrollo Regional (FEDER) of the European Union [CTQ2010-19217/BQU]
  3. Ministerio de Educacion of the Spanish Government [AP2007-01109]

向作者/读者索取更多资源

Several chromatographic systems (three systems of high-performance liquid chromatography and two micellar electrokinetic chromatography systems) besides the reference octanol water partition system are evaluated by a systematic procedure previously proposed in order to know their ability to model human skin permeation. The precision achieved when skin-water permeability coefficients are correlated against chromatographic retention factors is predicted within the framework of the solvation parameter model. It consists in estimating the contribution of error due to the biological and chromatographic data, as well as the error coming from the dissimilarity between the human skin permeation and the chromatographic systems. Both predictions and experimental tests show that all correlations are greatly affected by the considerable uncertainty of the skin permeability data and the error associated to the dissimilarity between the systems. Correlations with much better predictive abilities are achieved when the volume of the solute is used as additional variable, which illustrates the main roles of both lipophilicity and size of the solute to penetrate through the skin. In this way, the considered systems are able to give precise estimations of human skin permeability coefficients. In particular, the HPLC systems with common C18 columns provide the best performances in emulating the permeation of neutral compounds from aqueous solution through the human skin. As a result, a methodology based on easy, fast, and economical HPLC measurements in a common C18 column has been developed. After a validation based on training and test sets, the method has been applied with good results to the estimation of skin permeation of several hormones and pesticides. (C) 2013 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据