4.7 Article

Comparison of integrated whole-body [11C]choline PET/MR with PET/CT in patients with prostate cancer

期刊

出版社

SPRINGER
DOI: 10.1007/s00259-013-2467-y

关键词

PET/MR; PET/CT; Prostate cancer; Multimodal imaging

资金

  1. DFG (Deutsche Forschungsgemeinschaft, Grossgerateinitiative)
  2. Graduate School of Information Science in Health (GSISH)
  3. TUM Graduate School
  4. [SFB (Sonderforschungsbereich) 824]

向作者/读者索取更多资源

To evaluate the performance of conventional [C-11]choline PET/CT in comparison to that of simultaneous whole-body PET/MR. The study population comprised 32 patients with prostate cancer who underwent a single-injection dual-imaging protocol with PET/CT and subsequent PET/MR. PET/CT scans were performed applying standard clinical protocols (5 min after injection of 793 +/- 69 MBq [C-11]choline, 3 min per bed position, intravenous contrast agent). Subsequently (52 +/- 15 min after injection) PET/MR was performed (4 min per bed position). PET images were reconstructed iteratively (OSEM 3D), scatter and attenuation correction of emission data and regional allocation of [C-11]choline foci were performed using CT data for PET/CT and segmented Dixon MR, T1 and T2 sequences for PET/MR. Image quality of the respective PET scans and PET alignment with the respective morphological imaging modality were compared using a four point scale (0-3). Furthermore, number, location and conspicuity of the detected lesions were evaluated. SUVs for suspicious lesions, lung, liver, spleen, vertebral bone and muscle were compared. Overall 80 lesions were scored visually in 29 of the 32 patients. There was no significant difference between the two PET scans concerning number or conspicuity of the detected lesions (p not significant). PET/MR with T1 and T2 sequences performed better than PET/CT in anatomical allocation of lesions (2.87 +/- 0.3 vs. 2.72 +/- 0.5; p=0.005). The quality of PET/CT images (2.97 +/- 0.2) was better than that of the respective PET scan of the PET/MR (2.69 +/- 0.5; p = 0.007). Overall the maximum and mean lesional SUVs exhibited high correlations between PET/CT and PET/MR (rho=0.87 and rho=0.86, respectively; both p < 0.001). Despite a substantially later imaging time-point, the performance of simultaneous PET/MR was comparable to that of PET/CT in detecting lesions with increased [C-11]choline uptake in patients with prostate cancer. Anatomical allocation of lesions was better with simultaneous PET/MR than with PET/CT, especially in the bone and pelvis. These promising findings suggest that [C-11]choline PET/MR might have a diagnostic benefit compared to PET/CT in patients with prostate cancer, and now needs to be further evaluated in prospective trials.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据