4.7 Article

Biodistribution, radiation dosimetry and scouting of 90Y-ibritumomab tiuxetan therapy in patients with relapsed B-cell non-Hodgkin's lymphoma using 89Zr-ibritumomab tiuxetan and PET

出版社

SPRINGER
DOI: 10.1007/s00259-011-2008-5

关键词

Immuno-PET; Molecular imaging; Radioimmunotherapy; Ibritumomab tiuxetan; Zr-89; Y-90; Dosimetry; Lymphoma

向作者/读者索取更多资源

Purpose Positron emission tomography (PET) with Zr-89-britumomab tiuxetan can be used to monitor biodistribution of Y-90-ibritumomab tiuxetan as shown in mice. The aim of this study was to assess biodistribution and radiation dosimetry of 90Y-ibritumomab tiuxetan in humans on the basis of Zr-89-ibritumomab tiuxetan imaging, to evaluate whether co-injection of a therapeutic amount of Y-90-ibritumomab tiuxetan influences biodistribution of Zr-89-ibritumomabtiuxetan and whether pre-therapy scout scans with Zr-89-ibritumomab tiuxetan can be used to predict biodistribution of Y-90-ibritumomab tiuxetan and the dose-limiting organ during therapy. Methods Seven patients with relapsed B-cell non-Hodgkin's lymphoma scheduled for autologous stem cell transplantation underwent PET scans at 1, 72 and 144 h after injection of similar to 70 MBq Zr-89-ibritumomab tiuxetan and again 2 weeks later after co-injection of 15 MBq/kg or 30 MBq/kg Y-90-britumomab tiuxetan. Volumes of interest were drawn over liver, kidneys, lungs, spleen and tumours. Ibritumomab tiuxetan organ absorbed doses were calculated using OLINDA. Red marrow dosimetry was based on blood samples. Absorbed doses to tumours were calculated using exponential fits to the measured data. Results The highest Y-90 absorbed dose was observed in liver (3.2 +/- 1.8 mGy/MBq) and spleen (2.9 +/- 0.7 mGy/MBq) followed by kidneys and lungs. The red marrow dose was 0.52 +/- 0.04 mGy/MBq, and the effective dose was 0.87 +/- 0.14 mSv/MBq. Tumour absorbed doses ranged from 8.6 to 28.6 mGy/MBq. Correlation between predicted pre-therapy and therapy organ absorbed doses as based on Zr-89-ibritumomab tiuxetan images was high (Pearson correlation coefficient r=0.97). No significant difference between pre-therapy and therapy tumour absorbed doses was found, but correlation was lower (r=0.75). Conclusion Biodistribution of Zr-89-ibritumomab tiuxetan is not influenced by simultaneous therapy with Y-90-ibritumomab tiuxetan, and Zr-89-ibritumomab tiuxetan scout scans can thus be used to predict biodistribution and dose-limiting organ during therapy. Absorbed doses to spleen were lower than those previously estimated using In-111-ibritumomab tiuxetan. The dose-limiting organ in patients undergoing stem cell transplantation is the liver.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据