期刊
EUROPEAN JOURNAL OF ENVIRONMENTAL AND CIVIL ENGINEERING
卷 17, 期 6, 页码 478-495出版社
TAYLOR & FRANCIS LTD
DOI: 10.1080/19648189.2013.791071
关键词
corrosion; detection; probability of alarm; polarisation resistance; corrosion potential; concrete
A large experimental investigation was conducted in order to assess the capability of electrochemical techniques to detect the effective onset of carbonation-induced corrosion. Specimens made with CEM I, CEM II and CEM III cement-based concrete with embedded steel bars were subjected to several exposure conditions (wet/dry cycles, partial saturation and outdoor conditions) and tested. At regular time intervals, the polarisation resistance and free corrosion potential were measured, as was the amount of corrosion product. From the data acquired, and considering the experimental uncertainties, the probabilities of right or wrong alarm were estimated depending on the alarm thresholds for the electrochemical measurements and the threshold of the effective onset of corrosion. Optimum values of these thresholds were proposed on the basis of the receiver-operating-characteristic curve concept.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐