4.6 Article

The fate of the bicuspid valve aortopathy after aortic valve replacement

期刊

EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY
卷 45, 期 5, 页码 E128-E135

出版社

OXFORD UNIV PRESS INC
DOI: 10.1093/ejcts/ezt666

关键词

Aorta; Ascending aorta; Aortopathy; Bicuspid aortic valve

向作者/读者索取更多资源

The fate of the aortic dimensions in patients with a bicuspid aortic valve (BAV) after aortic valve replacement (AVR) is unclear. We investigated the evolution of aortic root and ascending aorta dimensions in patients with a BAV after AVR. To neutralize the effect of pathological transvalvular haemodynamics on aortic dimensions, we evaluated our hypotheses in patients with normal transvalvular haemodynamics after a subcoronary autograft procedure, which preserves intact the native aortic wall. We excluded patients operated on for endocarditis; who developed autograft insufficiency > trivial and who required autograft reoperation during the follow-up. We included 448 patients (361 with BAV; 340 males; 44.6 +/- 11.4 years; mean follow-up: 7.5 +/- 3.9 years). Valve phenotype was determined during surgery. Annual echocardiographic examinations (n = 3336) were performed (follow-up completeness: 98%). To allow for somatometric, gender and age influences, z-values of measurements were calculated from the general population (GP) and analysed using longitudinal methods. The increase in ascending aorta did not differ from that expected in the GP (0.04 z-values/year; P = 0.06). No difference could be observed in diameter increase rates between BAV and tricuspid aortic valve patients (TAV) (0.04 vs 0.06 z-values/year; P = 0.3), as well as between BAV phenotypes. The sinus increase did not differ from that expected in the GP (0.03 z-values/year; P = 0.1), and no significant differences could be observed between BAV phenotypes. In patients undergoing aortoplasty (n = 70), no significant difference in the rates of ascending aorta and sinus increase could be observed, compared with the GP. For the time period of this study and in patients with normal aortic root haemodynamics after AVR, ascending aorta dimensions over time are similar to that of the matched GP. Patients with a BAV did not exhibit higher rates of ascending aorta dilatation after AVR than patients with TAV. At least for the first postoperative decade, transvalvular haemodynamics appear to exhibit a greater influence than the genetic component of BAV on the development of the BAV aortopathy.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据