4.4 Article

A comparison of noninvasive bioreactance with oesophageal Doppler estimation of stroke volume during open abdominal surgery An observational study

期刊

EUROPEAN JOURNAL OF ANAESTHESIOLOGY
卷 30, 期 8, 页码 501-508

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/EJA.0b013e3283603250

关键词

-

资金

  1. generosity of the Anaesthesia Research Society

向作者/读者索取更多资源

CONTEXTThe anaesthetist must maintain tissue perfusion by ensuring optimal perioperative fluid balance. This can be achieved using less invasive cardiac output monitors such as oesophageal Doppler monitoring (ODM). Other less invasive cardiac output monitors using bio-impedence technology (noninvasive cardiac output monitoring, NICOM) may have a role in monitoring the circulation and informing fluid management decisions.OBJECTIVETo compare estimates of stroke volume from ODM with those from NICOM, a noninvasive monitor using bioreactance, a modification of transthoracic bio-impedence.DESIGNAn observational study.SETTINGManchester Royal Infirmary, UK. Data collected in 2011 and 2012.PARTICIPANTSTwenty-two patients scheduled for major, open abdominal surgery. Reasons for noninclusion: atrial fibrillation; heart failure; oesophageal disease; lack of capacity; and known sensitivity to colloid.INTERVENTIONAll patients had oesophageal Doppler cardiac output monitoring as a standard element of anaesthesia care. We placed NICOM Bioreactance electrodes and recorded stroke volume estimates from both devices. Fluid challenges were given by the anaesthetist and the haemodynamic responses were recorded.MAIN OUTCOME MEASUREStroke volume during surgery. The Bland-Altman method was used to compare bias and limits of agreement for stroke volume and cardiac output. Fluid responders were defined as patients who increased stroke volume by at least 10% after fluid loading. The precision of each device was calculated during periods of haemodynamic stability.RESULTSWe made 788 acceptable measurements of cardiac output. The bias was -6.9ml and the limits of agreement were -22.9 to 36.8ml. The percentage error was 57%. Average precision for both the ODM and NICOM were similar, 8.5% (SD 5.4%) and 8.7% (SD 3.2%). The concordance for the stroke volume change following fluid challenge was 90.5%. Both devices produced unacceptable readings with electrical diathermy.CONCLUSIONSimultaneous stroke volume estimations made by noninvasive Bioreactance (NICOM) and oesophageal Doppler showed bias and limits of agreement that are not clinically acceptable. The measurements made by these two devices cannot be regarded as interchangeable.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据