4.4 Article

A xenon recirculating ventilator for the newborn piglet: developing clinical applications of xenon for neonates

期刊

EUROPEAN JOURNAL OF ANAESTHESIOLOGY
卷 29, 期 12, 页码 577-585

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/EJA.0b013e3283583c4b

关键词

anaesthesia; closed circuit ventilation; neonate; neuroprotection; xenon

资金

  1. Air Products PLC, Basingstoke, England
  2. UK Department of Health's National Institute for Health Research Biomedical Research Centres funding scheme

向作者/读者索取更多资源

Context The clinical applications of xenon for the neonate include both anaesthesia and neuroprotection. However, due to the limited natural availability of xenon, special equipment is required to administer and recapture the gas to develop xenon as a therapeutic agent. Objective In order to test the xenon recirculating ventilator for the application of neuroprotection in a preclinical trial, our primary objective was to test the efficiency, reliability and safety of administering 50% xenon for 24 h in hypoxic ischaemic piglets. Design A prospective observational study. Setting Institute for Women's Health, University College London, January 2008 to March 2008. Animals Four anaesthetised male piglets, less than 24 h old, underwent a global hypoxic ischaemic insult for approximately 25 min prior to switching to the xenon recirculating ventilator. Intervention Between 2 and 26 h after hypoxic ischaemia, anaesthetised piglets were administered a mixture of 50% xenon, air, oxygen and isoflurane. Main outcome measures The primary outcome measure was blood gas PaCO2 (kPa) and secondary outcome measure was xenon gas use (l h(-1)), over the 24-h duration of xenon administration. Results The xenon recirculating ventilator provided effective ventilation, automated control of xenon/air gas mixtures, and stable blood gas PaCO2 (4.5 to 6.3 kPa) for 24 h of ventilation with the xenon recirculating ventilator. Total xenon use was minimal at approximately 0.6 l h(-1) at a cost of approximately (sic)8h(-1). Additional features included an isoflurane scavenger and bellows height alarm. Conclusion Stable gas delivery to a piglet with minimal xenon loss and analogue circuitry made the xenon recirculating ventilator easy to use and it could be modified for other large animals and noble gas mixtures. The technologies, safety and efficiency of xenon delivery in this preclinical system have been taken forward in the development of neonatal ventilators for clinical use in phase II clinical trials for xenon-augmented hypothermia and for xenon anaesthesia. Eur J Anaesthesiol 2012; 29: 577-585 Published online 23 August 2012

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据