4.7 Article

Biodegradable-polymer drug-eluting stents vs. bare metal stents vs. durable-polymer drug-eluting stents: a systematic review and Bayesian approach network meta-analysis

期刊

EUROPEAN HEART JOURNAL
卷 35, 期 17, 页码 1147-+

出版社

OXFORD UNIV PRESS
DOI: 10.1093/eurheartj/eht570

关键词

Bare metal stents; Drug-eluting stents; Biodegradable polymer drug-eluting stents; Meta-analysis

资金

  1. Seoul National University Hospital Research Fund
  2. Bio & Medical Technology Development Program of the National Research Foundation (NRF) - Korean Government [2010-0020258]
  3. National Research Foundation of Korea [2010-0020258] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

向作者/读者索取更多资源

Background The aim of this study was to compare the safety and efficacy of biodegradable-polymer (BP) drug-eluting stents (DES), bare metal stents (BMS), and durable-polymer DES in patients undergoing coronary revascularization, we performed a systematic review and network meta-analysis using a Bayesian framework. Methods and Results Study stents included BMS, paclitaxel-eluting (PES), sirolimus-eluting (SES), endeavor zotarolimus-eluting (ZES-E), cobalt-chromium everolimus-eluting (CoCr-EES), platinium-chromium everolimus-eluting (PtCr-EES), resolute zotarolimus-eluting (ZES-R), and BP biolimus-eluting stents (BP-BES). After a systematic electronic search, 113 trials with 90 584 patients were selected. The principal endpoint was definite or probable stent thrombosis (ST) defined according to the Academic Research Consortium within 1 year. Results Biodegradable polymer-biolimus-eluting stents [OR, 0.56; 95% credible interval (CrI), 0.33-0.90], SES (OR, 0.53; 95% CrI, 0.38-0.73), CoCr-EES (OR, 0.34; 95% CrI, 0.23-0.52), and PtCr-EES (OR, 0.31; 95% CrI, 0.10-0.90) were all superior to BMS in terms of definite or probable ST within 1 year. Cobalt-chromium everolimus-eluting stents demonstrated the lowest risk of ST of all stents at all times after stent implantation. Biodegradable polymer-biolimus-eluting stents was associated with a higher risk of definite or probable ST than CoCr-EES (OR, 1.72; 95% CrI, 1.04-2.98). All DES reduced the need for repeat revascularization, and all but PES reduced the risk of myocardial infarction compared with BMS. Conclusions All DESs but PES and ZES-E were superior to BMS in terms of ST within 1 year. Cobalt-chromium everolimus-eluting stents was safer than any DES even including BP-BES. Our results suggest that not only the biodegradability of polymer, but the optimal combination of stent alloy, design, strut thickness, polymer, and drug all combined determine the safety of DES.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据