4.7 Article

Epicardial wave mapping in human long-lasting persistent atrial fibrillation: transient rotational circuits, complex wavefronts, and disorganized activity

期刊

EUROPEAN HEART JOURNAL
卷 35, 期 2, 页码 86-97

出版社

OXFORD UNIV PRESS
DOI: 10.1093/eurheartj/eht267

关键词

Atrial fibrillation

资金

  1. National Health and Medical Councils of Australia

向作者/读者索取更多资源

Objectives To characterize the nature of atrial fibrillation (AF) activation in human persistent AF (PerAF) using modern tools including activation, directionality analyses, complex-fractionated electrogram, and spectral information. Background The mechanism of PerAF in humans is uncertain. Methods and results High-density epicardial mapping (128 electrodes/6.75 cm(2)) of the posterior LA wall (PLAW), LA and RA appendage (LAA, RAA), and RSPV-LA junction was performed in 18 patients with PerAF undergoing open heart surgery. Continuous 10 s recordings were analysed offline. Activation patterns were characterized into four subtypes (i) wavefronts (broad or multiple), (ii) rotational circuits (>= 2 rotations of 360), (iii) focal sources with centrifugal activation of the entire mapping area, or (iv) disorganized activity [isolated chaotic activation(s) that propagate <= 3 bipoles or activation(s) that occur as isolated beats dissociated from the activation of adjacent bipole sites]. Activation at a total of 36 regions were analysed (14 PLAW, 3 RSPV-LA, 12 LAA, and 7 RAA) creating a database of 2904 activation patterns. In the majority of maps, activation patterns were highly heterogeneous with multiple unstable activation patterns transitioning from one to another during each recording. A mean of 3.8 +/- 1.6 activation subtypes was seen per map. The most common patterns seen were multiple wavefronts (56.2 +/- 32) and disorganized activity (24.2 +/- 30.3). Only 2 of 36 maps (5.5) showed a single stable activation pattern throughout the 10-s period. These were stable planar wavefronts. Three transient rotational circuits were observed. Two of the transient circuits were located in the posterior left atrium, while the third was located on the anterior surface of the LAA. Focal activations accounted for 11.3 +/- 14.2 of activations and were all short-lived (<= 2 beats), with no site demonstrating sustained focal activity. Conclusion Human long-lasting PerAF is characterized by heterogeneous and unstable patterns of activation including wavefronts, transient rotational circuits, and disorganized activity.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据