4.7 Article

Randomized trial of three rapamycin-eluting stents with different coating strategies for the reduction of coronary restenosis

期刊

EUROPEAN HEART JOURNAL
卷 29, 期 16, 页码 1975-1982

出版社

OXFORD UNIV PRESS
DOI: 10.1093/eurheartj/ehn253

关键词

biodegradable; coronary restenosis; drug-eluting stents; polymer; rapamycin

向作者/读者索取更多资源

The objective of this study was to assess the non-inferiority, in terms of anti-restenotic efficacy, of both biodegradable-polymer (BP) and polymer-free (PF) stents compared with permanent-polymer rapamycin-eluting (PP; Cypher) stent. Patients with de novo coronary lesions in native vessels were randomly assigned to receive a BP stent, a PF stent or a PP stent. The primary endpoint was in-stent late lumen loss at follow-up angiogram. A total of 605 patients were enrolled: 202 patients received BP stents, 202 were treated with PP stents, and 201 received PF stents. Repeat angiography was available for 492 patients (81.3%). Mean late lumen loss at 6-8-month angiographic follow-up was 0.17 +/- 0.45 mm in the BP stent group, 0.23 +/- 0.46 mm in the PP cohort, and 0.47 +/- 0.56 mm in the PF stent group. The BP stent met pre-specified criteria for non-inferiority (P < 0.001), whereas the PF stent did not (P = 0.94). There were no differences in safety outcomes. Both BP and PF stents have a 1-year safety profile similar to that of the PP stent. Whereas the PF stent provided an inferior efficacy, the BP stent is at least as effective as the PP stent in terms of anti-restenotic efficacy.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据