4.6 Article

Implications of bipolar voltage mapping and magnetic resonance imaging resolution in biventricular scar characterization after myocardial infarction

期刊

EUROPACE
卷 21, 期 1, 页码 163-174

出版社

OXFORD UNIV PRESS
DOI: 10.1093/europace/euy192

关键词

Magnetic resonance imaging; T1 mapping; Myocardial infarction; Voltage mapping; Myocardial substrate

资金

  1. Ministry of Economy, Industry and Competitiveness (MEIC)
  2. Pro CNIC Foundation
  3. CNIC [SEV-2015-0505]
  4. BSC (Barcelona, Spain) [SEV-2011-0067]
  5. Instituto de Salud Carlos III, Fondo Europeo de Desarrollo Regional [RD12/0042/0036, CB16/11/00458]
  6. Spanish Ministry of Economy and Competitiveness (MINECO) [SAF2016-80324-R, PI16/02110, DTS17/00136]
  7. European Commission [JTC2016/APCIN-ISCIII-2016, AC16/00021]
  8. Fundacion Interhospitalaria para la Investigacion Cardiovascular (FIC, Madrid, Spain)
  9. heart rhyhtm section of the Spanish Society of Cardiology
  10. National Heart Lung and Blood Institute, USA, National Institutes of Health [HL122352]
  11. CompBioMed project European Union's Horizon 2020 research and innovation program [H2020-EU.1.4.1.3, 675451]
  12. 'la Caixa' Fellowship Grant for Doctoral Studies, 'la Caixa' Banking Foundation, Barcelona, Spain

向作者/读者索取更多资源

Aims We aimed to study the differences in biventricular scar characterization using bipolar voltage mapping compared with state-of-the-art in vivo delayed gadolinium-enhanced cardiac magnetic resonance (LGE-CMR) imaging and ex vivo T1 mapping. Methods and results Ten pigs with established myocardial infarction (MI) underwent in vivo scar characterization using LGE-CMR imaging and high-density voltage mapping of both ventricles using a 3.5-mm tip catheter. Ex vivo post-contrast T1 mapping provided a high-resolution reference. Voltage maps were registered onto the left and right ventricular (LV and RV) endocardium, and epicardium of CMR-based geometries to compare voltage-derived scars with surface-projected 3D scars. Voltage-derived scar tissue of the LV endocardium and the epicardium resembled surface projections of 3D in vivo and ex vivo CMR-derived scars using 1-mm of surface projection distance. The thinner watt of the RV was especially sensitive to lower resolution in vivo LGE-CMR images, in which differences between normalized low bipolar voltage areas and CMR-derived scar areas did not decrease below a median of 8.84% [interquartile range (IQR) (3.58, 12.70%)]. Overall, voltage-derived scars and surface scar projections from in vivo LGE-CMR sequences showed larger normalized scar areas than high-resolution ex vivo images [12.87% (4.59, 27.15%), 18.51% (11.25, 24.61%), and 9.30% (184, 19.59%), respectively], despite having used optimized surface projection distances. Importantly, 43.02% (36.54, 48.72%) of voltage-derived scar areas from the LV endocardium were classified as non-enhanced healthy myocardium using ex vivo CMR imaging. Conclusion In vivo LGE-CMR sequences and high-density voltage mapping using a conventional linear catheter fail to provide accu- rate characterization of post-MI scar, limiting the specificity of voltage-based strategies and imaging-guided procedures.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据