4.6 Article

Incidence and predictors of anti-bradycardia pacing in patients with Anderson-Fabry disease

期刊

EUROPACE
卷 13, 期 12, 页码 1781-1788

出版社

OXFORD UNIV PRESS
DOI: 10.1093/europace/eur267

关键词

Anderson-Fabry disease; Sinus node dysfunction; Atrio-ventricular node dysfunction; Cardiac pacing; Sudden cardiac death

资金

  1. Shire HGT
  2. Genzyme Inc.
  3. Spanish Society of Cardiology
  4. British Heart Foundation
  5. European Society of Cardiology
  6. Department of Health's NIHR Biomedical Research Centres

向作者/读者索取更多资源

Background Anderson-Fabry disease (AFD) is an X-linked lysosomal storage disorder associated with bradyarrhythmias. We sought to examine the nature of conduction system abnormalities and the indications and determinants of anti-bradycardia pacing in patients with AFD. Methods and results We studied 204 patients with AFD (49% male, mean age 42 years) in an observational, longitudinal, retrospective cohort study. At baseline, 5 (2.5%) patients had pacemakers for the treatment of bradycardias [4/5 (80%) for atrioventricular disease; 1/5 (20%) for sinus node disease]. PR interval <120 ms was observed in 15 (7%); PR interval >200 ms in 6 (3%); QRS interval >120 ms 18 (9%); left QRS axis deviation in 16 (8%); and right-axis deviation in 2 (1%). Age was an independent determinant of prolonged PR interval, QRS duration and left QRS axis deviation. During follow-up (189 patients; 899 patient-years), 12 (6%) had a device implanted to treat spontaneously occurring bradyarrhythmias [5/12 (42%) for atrioventricular disease; 7/12 (58%) sinus node disease] with 8% 5-year cumulative incidence. Two independent predictors of future anti-bradycardia pacing were identified in a multivariable Cox model: QRS duration [hazard ratio (HR) 1.05, 95% confidence intervals (CI) 1.02-1.09, P = 0.001; receiver operating characteristic (ROC) curve c-statistic 0.726] and PR interval duration (HR 1.03, 95% CI 1.004-1.060, P = 0.023; ROC curve c-statistic 0.548). QRS duration >= 110 ms at baseline had a sensitivity of 64%, specificity of 84%, 49% positive predictive value, and 91% negative predictive value for identifying patients likely to require anti-bradycardia pacing. Conclusion In patients with AFD increasing age is associated with PR and QRS interval prolongation and left QRS axis deviation. Pacing for atrioventricular and sinus node disease is common and patients with QRS >= 110 ms should be closely monitored for bradyarrhythmias.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据