Reasons for performing study: This study investigated the use of a wireless ambulatory capsule (WAC; SmartPill (R) pH.p GI Monitoring System) to determine WAC-gastric emptying time (GET) in ponies. Objectives: To measure WAC-GET and compare it to those findings with GET assessed by nuclear scintigraphy (S-GET). Hypothesis: WAC-GET will be slower than S-GET, but will be significantly correlated. Methods: Seven healthy adult mixed-breed pony mares were used in this study. Feed was withheld for 12 h prior to the WAC administration. After administration, a complete-feed diet was fed to allow the WAC to pass into the stomach. Luminal pH, temperature and pressure were collected by a modified receiver secured to the pony. Once the pH reached a value of =8.0, it was determined that gastric emptying had occurred, and ponies were fed grass hay. After 5 days, data were downloaded and analysed using proprietary software. During the second period of the study, after at least 2 weeks, 4 of the ponies underwent a standard S-GET test. Results: The WAC was successfully administered, and data were collected from all ponies. The mean percentage of data packets collected by the receiver was 84.9 +/- 3.51% (range 66.895.1%). Mean WAC-GET was 7.38 h (range 0.1546.65 h). Mean gastric pH was 4.75 (range 2.076.99). Mean small intestinal transit time was 4.6 h. The mean pH for the small intestine was 8.0. The mean S-GET time (in hours) when 10% of the radioactive feed is present in the stomach (T-90%) was 2.3 h. The S-GET did not correlate significantly with the WAC-GET. Conclusions and potential relevance: The WAC was safely administered to ponies, and data were collected using a modified receiver. The WAC-GET varied considerably between ponies, but was =3 h in 5 of the 6 ponies. The WAC used in this study provided a noninvasive technique that produced novel information about the pony gastrointestinal tract, but owing to the substantial variability in GET values and long transit time it may not be a reliable clinical tool at this time.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据