4.3 Article

Patient-specific targeting guides compared with traditional instrumentation for glenoid component placement in shoulder arthroplasty: a multi-surgeon study in 70 arthritic cadaver specimens

期刊

JOURNAL OF SHOULDER AND ELBOW SURGERY
卷 24, 期 6, 页码 965-971

出版社

MOSBY-ELSEVIER
DOI: 10.1016/j.jse.2014.10.013

关键词

Total shoulder arthroplasty; patient-specific targeting guides; standard guides; cadaver study; component placement

向作者/读者索取更多资源

Hypothesis and background: The purpose of this study was to compare the accuracy of patient-specific guides for total shoulder arthroplasty (TSA) with traditional instrumentation in arthritic cadaver shoulders. We hypothesized that the patient-specific guides would place components more accurately than standard instrumentation. Materials and methods: Seventy cadaver shoulders with radiographically confirmed arthritis were randomized in equal groups to 5 surgeons of varying experience levels who were not involved in development of the patient-specific guidance system. Specimens were then randomized to patient-specific guides based off of computed tomography scanning, standard instrumentation, and anatomic TSA or reverse TSA. Variances in version or inclination of more than 10 degrees and more than 4 mm in starting point were considered indications of significant component malposition. Results: TSA glenoid components placed with patient-specific guides averaged 5 degrees of deviation from the intended position in version and 3 degrees in inclination; those with standard instrumentation averaged 8 degrees of deviation in version and 7 degrees in inclination. These differences were significant for version (P = .04) and inclination (P = .01). Multivariate analysis of variance to compare the overall accuracy for the entire cohort (TSA and reverse TSA) revealed patient-specific guides to be significantly more accurate (P = .01) for the combined vectors of version and inclination. Patient-specific guides also had fewer instances of significant component malposition than standard instrumentation did. Conclusion: Patient-specific targeting guides were more accurate than traditional instrumentation and had fewer instances of component malposition for glenoid component placement in this multi-surgeon cadaver study of arthritic shoulders. Long-term clinical studies are needed to determine if these improvements produce improved functional outcomes. (C) 2015 Journal of Shoulder and Elbow Surgery Board of Trustees.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据