4.2 Article

High frequency oscillations and seizure frequency in patients with focal epilepsy

期刊

EPILEPSY RESEARCH
卷 85, 期 2-3, 页码 287-292

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.eplepsyres.2009.03.026

关键词

Intracranial electrodes; Epilepsy surgery; Ripple; Fast ripple; Seizure prediction

资金

  1. Canadian Institutes of Health Research [MOP-10189]
  2. Netherlands Organization for Scientific Research (NWO) [92003481]
  3. University Medical Center Utrecht

向作者/读者索取更多资源

High frequency oscillations (HFOs) have been associated with epileptogenicity. In rats, the extent of HFOs (>200 Hz) is correlated with seizure frequency. We studied whether the same applies to patients with focal epilepsy. Thirty-nine patients with intracerebral EEG sampled at 2000 Hz were studied for interictal ripples (80-250 Hz), fast ripples (FR, 250-500 Hz) and spikes. Seizure frequency before implantation was compared to numbers of channels with HFOs (>1 /min). Analyses were repeated for HFO rates of >5, >10 and >20. Separate analyses were done for 25 patients with temporal lobe epilepsy only and for a selection of similar unilateral temporal channels in 12 patients. No linear correlation or trend was found relating the number of channels with HFOs and seizure frequency. There was a linear positive correlation between the number of channels with more than 20 FRs/min and seizure frequency. The hypothesis that the more tissue generating HFOs, the higher the seizure frequency, was not confirmed, though there might be a correlation for high FR rates. (C) 2009 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据