4.4 Article

Comparison of coagulation and MIEX pre-treatment processes for bacterial and turbidity removal, utilizing real-time optical monitoring techniques

期刊

ENVIRONMENTAL TECHNOLOGY
卷 35, 期 8, 页码 1038-1045

出版社

TAYLOR & FRANCIS LTD
DOI: 10.1080/09593330.2013.859737

关键词

log removal; coagulation; MIEX; photometric dispersion analyser (PDA); flow cytometry; floc breakage

向作者/读者索取更多资源

Jar testing and flow cytometry were used in conjunction with photometric dispersion analysis (PDA) to assess conventional alum coagulation with and without magnetic ion exchange (MIEX) pre-treatment for turbidity and bacterial removal capacity. Treatment assessment included powdered activated carbon (PAC) and pre-chlorination of the MIEX-treated raw water. Floc particles were subjected to shear forces after settling and re-suspended to gauge bacterial release potential, floc breakage and re-aggregation. MIEX in conjunction with alum coagulation achieved improved coagulation as measured by PDA but did not increase bacterial log removal value (LRV) in comparison with conventional coagulation. Pre-chlorination and PAC addition were seen to improve bacterial removal and coagulation, respectively, but were less effective for bacterial LRVs when they were used in conjunction during coagulation.