4.3 Article

Development of Molecular Imprinted Polymer for Selective Adsorption of Benz[a]pyrene Among Airborne Polycyclic Aromatic Hydrocarbon Compounds

期刊

ENVIRONMENTAL ENGINEERING SCIENCE
卷 28, 期 6, 页码 421-434

出版社

MARY ANN LIEBERT INC
DOI: 10.1089/ees.2010.0268

关键词

molecular imprinted polymer; sample pretreatment; solid-phase extraction; cigarette mainstream smoke; toxicity separation

资金

  1. National Science Council of the Republic of China, Taiwan [NSC 95-2221-E-006-175]

向作者/读者索取更多资源

This study combined molecular imprinted polymers (MIPs) and solid-phase extraction (SPE) to create a novel sample pretreatment technique for chemical analysis of polycyclic aromatic hydrocarbons (PAHs) in cigarette smoke. Experimental results demonstrated that MIPs have good selectivity for benz[a] pyrene (BaP) among mixtures of 16 PAH solutions. Molecular imprinted SPE (MISPE) cartridges were applied to a sample taken from mainstream smoke from a cigarette. Based on functional monomer and crosslinker, this study investigated four groups of MIPs. After each template was removed, tests on capacity, selectivity, recovery, scanning electron microscope observations, and real environmental sample tests were conducted. Experimental results showed that MIP-3 (methacrylic acid-co-trimethylolpropane trimethacrylate) is the best MIP, with a capacity of 7.80 +/- 0.8 (mu g/g), BaP selectivity exceeding 84%, and recovery exceeding 80%. In the environmental sample tests, that is, mainstream smoke from reference cigarettes 3R4F, 87% of BaP was adsorbed by the MISPE cartridge compared with that adsorbed by the filters. All experimental results suggested that MISPE can more effectively adsorb BaP among the 16 different PAHs in mixtures, reduce background interferences, and increase signal resolution as compared with traditional extraction techniques. Additionally, using MISPE cartridges in sample pretreatment reduced both the analysis time and the amount of organic solvent used. In addition, using MISPE may also extract toxic target analytes from a complex sample selectively and more effectively than traditional Soxhlet extraction. Combination of MIP-3 and SPE for environmental sample pretreatment offers a useful tool for selective isolation of the mutagenic PAHs. This study is also the first to apply an MISPE cartridge in the analysis of trace-level BaP in cigarette smoke.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据