4.8 Article

Assaying organochlorines in archived serum for a large, long-term cohort: Implications of combining assay results from multiple laboratories over time

期刊

ENVIRONMENT INTERNATIONAL
卷 37, 期 4, 页码 709-714

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.envint.2011.01.013

关键词

CV; Assay library; Organochlorines; Measurement error; Biomarkers; Epidemiology

资金

  1. National Institute of Environmental Health Sciences [R01 ES08345, R29 ES09042, R01 ES12460, 1R01 ES017024]
  2. National Cancer Institute [R01 CA72919]
  3. National Institutes of Child Health and Human Development [N01 DK63422, N01 HD63258]
  4. Lance Armstrong Foundation

向作者/读者索取更多资源

Conserving irreplaceable, archived serum samples may sometimes conflict with the objective of minimizing measurement error due to laboratory effects. We sought to determine whether we could successfully combine assay results for DDT-related compounds and polychlorinated biphenyls (PCBs) in serum from the same birth cohort obtained from different laboratories over time. Using the Child Health and Development Studies (CHDS) serum archive, we compared variability for assays of a quality control pool to variability for assays of subject serum. The quality control pool was created from native archived serum samples that were pooled, then aliquoted, blinded and inserted pair-wise into assay batches along with the subject serum for 5 studies using CHDS samples conducted over a 13 year period by three different laboratories. We found that the variability between laboratory and over time within laboratory was small relative to inter-individual variability for p,p'-DDT (1,1,1-trichloro-2,2-bis(p-chlorophenyl)ethane), p,p'-DDE (1,1'-dichloro-2,2'-bis(p-chlorophenyl)ethylene) and o,p'-DDT (1,1,1-trichloro-2-(p-chloropheny1)-2-(o-chlorophenyl)-ethane). Results were also consistent for most PCB congeners which were detectable in 85% or more of samples. Our results suggest that it is possible to combine assays for DDT and PCB congeners measured at positive levels as they are accumulated for cohort subjects without risking meaningful misclassification due to variation stemming from laboratory or time period. This has significant implications for future study costs, conservation of irreplaceable archived samples and for leveraging past investments for future research. For PCB congeners with very low levels, findings caution against pooling of assays without further exploration. (C) 2011 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据