4.8 Article

Brominated flame retardants in offices in Michigan, USA

期刊

ENVIRONMENT INTERNATIONAL
卷 36, 期 6, 页码 548-556

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.envint.2010.04.008

关键词

Air exchange rate; Buildings; Brominated flame retardants; Exposure; Filters; Indoor air quality; Indoor air; PBDE

资金

  1. US Environmental Protection Agency's Great Lakes National Program Office
  2. Great Lakes Commission

向作者/读者索取更多资源

Brominated flame retardants (BFRs) are now ubiquitous contaminants with large reservoirs and high concentrations in buildings. Most of the information documenting BFR levels has been obtained in residences, and other environments that can lead to exposure have received relatively little attention, including offices that contain numerous BFR sources and where individuals spend considerable time. The aim of this study is to characterize BFR concentrations, potential emission sources, and migration pathways in office environments. We measure BFR levels in floor dust, indoor air, ventilation filter dust, and carpets in ten commercial and institutional buildings in Michigan, U.S.A. The median concentration of total BDEs in settled dust was 8754 ng g(-1), at the upper range of levels previously reported. Especially elevated levels were found in offices in buildings that contained known or likely BFR sources, e.g., computer servers. A trends analysis in a newly constructed building showed remarkable increases in concentrations of BFRs in settled dust and indoor air, and apparent steady-state levels were reached 5 to 8 months after building completion, a particularly striking finding given that the building was constructed and furnished several years after the voluntary phase-out of the penta- and octa-mixtures. Airborne particulate matter collected in a building's HVAC system filters contained PBDEs, including BDE-209, at levels exceeding the concentration of floor dust. In conjunction with estimates of building air flow rates, filter efficiency and other parameters, mass balance calculations for this building were used to estimate the emission rates and reservoirs of PBDEs. The widespread distribution of BFRs found in offices in both new and old buildings suggests the significance of workplace exposures, the need for controls to minimize human exposure, intra-building migration, and environmental releases of these chemicals, and the need for monitoring in new buildings to confirm the effectiveness of the PBDE phase-out. (C) 2010 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据