4.7 Article

Experimental load rating of aged railway concrete sleepers

期刊

ENGINEERING STRUCTURES
卷 76, 期 -, 页码 147-162

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.engstruct.2014.06.032

关键词

Prestressed concrete sleeper; Load rating; Remaining life; Experimental impact testing; Failure mode; Ballasted railway track; Transport infrastructure; Risk and safety

资金

  1. ROCLA
  2. KCPM, Australia
  3. Abetong AB, Sweden
  4. Structural Lab Manager Alan Grant
  5. Australian Government's Department of Innovation
  6. Endeavour Executive Fellowships at Department of Civil and Environmental Engineering
  7. Massachusetts Institute of Technology, Cambridge MA, USA
  8. Kennedy School of Government, Harvard University, MA, USA
  9. Railway Mechanics Centre, Chalmers University of Technology, Gothenburg, Sweden

向作者/读者索取更多资源

Prestressed concrete sleepers (or railroad ties) are structural members that distribute the wheel loads from the rails to the track support system. Over a period of time, the concrete sleepers age and deteriorate in addition to experiencing various types of static and dynamic loading conditions, which are attributable to train operations. Recent studies have established two main limit states for the design consideration of concrete sleepers: ultimate limit states under extreme impact and fatigue limit states under repeated probabilistic impact loads. It was noted that the prestress level has a significant role in maintaining the high endurance of the sleepers under low to moderate repeated impact loads. This experimental investigation was aimed at static and dynamic load rating of aged railway concrete sleepers after service. Fifteen sleepers were extracted from a heavy haul rail network for testing using experimental facilities at the University of Wollongong (UoW), Australia. The structural evaluation program included quasi-static bending tests, dynamic impact tests, and tests to establish the current level of prestress in the steel wires using the dynamic relaxation technique. Two of the sleepers were evaluated for the level of prestressing forces in accordance with Australian Standards. Through diagnostic tests, the results of quasi-static bending tests produced the in-track bending capacities of sleepers that can be combined with the moments and forces anticipated over the next ten years to predict performance of the sleepers on a heavy haul coal line. The dynamic tests simulating the ability of concrete sleepers to resist extreme loading events due to heavy impact loads demonstrated that the sleepers in-track are likely to be able to resist the planned increased traffic without catastrophic failure over the next decade. Final conclusions suggest that there should be a routine test program every five years to ascertain the load rating of clustered sleepers and their fastening system in the heavy haul track system. (C) 2014 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据