4.7 Article

Behaviour of beam-to-column high strength steel endplate connections under fire conditions - Part 1: Experimental study

期刊

ENGINEERING STRUCTURES
卷 64, 期 -, 页码 23-38

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.engstruct.2014.01.028

关键词

High strength steel; Endplate connection; Beam-to-column connections; Structural fire performance; Experimental study

向作者/读者索取更多资源

In order to reveal more information and understanding on behaviour and failure mechanisms of high strength steel endplate connections under fire conditions, an experimental study has been carried out and presented in this paper. Full-scale tests on beam-to-column high strength steel endplate connections were conducted at elevated temperature 550 degrees C under steady state fire condition and at ambient temperature as reference. Further, their behaviour was compared with that of mild steel endplate connections. Moreover, the provisions of Eurocode 3 were validated with test results of high strength steel endplate connections. It is found that a proper thinner high strength steel endplate can enhance the connection's rotation capacity both at ambient temperature and in fire (which guarantees the safety of an entire structure), and simultaneously achieve almost the same moment resistance with a mild steel endplate connection. (C) 2014 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据