4.7 Article

Reliability-based evaluation of the inherent safety presumptions in common fire safety design

期刊

ENGINEERING STRUCTURES
卷 77, 期 -, 页码 181-192

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.engstruct.2014.06.007

关键词

Concrete slabs; Structural fire design; Safety level; Monte Carlo simulations; Fire ignition frequency

资金

  1. FWO

向作者/读者索取更多资源

The structural safety of a simply supported one-way concrete slab exposed to the ISO 834 standard fire curve is investigated. The proposed methodology allows for an objective comparison of the structural performance of different concrete slab design alternatives and to derive indirectly a lower bound of the fire ignition frequencies that can be associated to the Eurocode guidelines. A comparison is made with empirical fire ignition frequencies found in literature and a detailed study is presented of the significance of the concrete cover and its uncertainty on the safety level and fire resistance time. Results indicate that the safety level during fire and the fire resistance time are both highly sensitive to the ratio of the variable to the permanent load and that the accepted design solutions given in EN 1992-1-2 are rather conservative. (C) 2014 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据