4.7 Article

Dynamic reduction-based structural damage detection of transmission towers: Practical issues and experimental verification

期刊

ENGINEERING STRUCTURES
卷 33, 期 5, 页码 1459-1478

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.engstruct.2011.01.009

关键词

Structural damage detection; Model reduction; Transmission tower; Modal identification; Modeling error; Sensor placement

资金

  1. City University of Hong Kong, Kowloon, Hong Kong [7002589]

向作者/读者索取更多资源

Structural damage detection in large-scale three-dimensional spatial structures is a challenging problem. It is impractical to develop a general damage-detection method that is applicable to all types of structural systems and all kinds of damage. A practical and efficient structural damage detection method must consider the characteristics of the target structure and damage in the development stage. In 2009, Yin et al. [33] proposed a damage detection method for the health monitoring of transmission towers. The method was developed based on the dynamical finite element (FE) model reduction technique, which utilizes identified modal parameters, such as natural frequencies and mode shapes, with only a limited number of sensors. In Ref. [33], the proposed method was numerically verified by simulated noisy data from a three-dimensional transmission tower model for single and multiple damage cases. This paper discusses some practical issues related to the proposed method, such as sensor placement and computational efficiency. Rather than proposing a general sensor placement method, a set of preliminary sensor locations is determined based on engineering judgement. This set of sensor locations is then checked against the results of a sensitivity analysis to ensure that the measured data contain information for identifying all of the target damage scenarios. To reduce the required computational power, two simplified versions of the proposed method are presented. The proposed method is then verified with a scaled-down model of a transmission tower (2.4 m high) that was built at the Structural Vibration Laboratory (SVL) of the City University of Hong Kong. This paper reports the detailed experimental setup and the method of extracting the modal parameters from a series of free vibration tests with only a limited number of sensors. The verification results show that the proposed damage detection method identifies the damaged sub-structures in all of the experimental cases considered. It must be pointed out that the transmission tower structure, in its operating conditions, suffers from the effect of the forces transmitted from the cables it carries. The influence of this force on the damage identification result is great and can not be neglected in practice. In the present experimental case study, only a transmission tower-like structure without carrying the cables is investigated in laboratory conditions. (C) 2011 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据