期刊
ENGINEERING FAILURE ANALYSIS
卷 18, 期 1, 页码 354-363出版社
PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.engfailanal.2010.09.014
关键词
Steel bridge; Retrofitted details; Long-term monitoring; Fatigue reliability
资金
- Southeast University
This paper presents the field stress and displacement measurements in controlled load tests and long-term monitoring to investigate the performance of two retrofitted details which were used to alleviate the cracking problems of an existing steel bridge Effectiveness of the retrofit schemes is demonstrated by comparing the displacements of the retrofitted details with those of the non-retrofitted ones Based on the field monitored data and the AASHTO Specifications time-dependent fatigue reliability assessment is made in which S-N curves are used to consider the influence of variable amplitude loading on the propagation of initial defects and fatigue damage Effective stress ranges are derived from daily stress range histograms and lognormal probability density functions (PDFs) are used to model the uncertainties in the effective stress range with the aid of regression analyses It is observed that stress ranges in the instrumented details are all below the corresponding constant amplitude fatigue limits Consequently high fatigue reliabilities of these retrofitted details are expected However the reliability indices decrease significantly as time goes on and this deterioration process may be accelerated with the increase in traffic volume The analysis results provide references to bridges with similar fatigue cracking problems (C) 2010 Elsevier Ltd All rights reserved
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐