期刊
JOURNAL OF POWER SOURCES
卷 281, 期 -, 页码 103-113出版社
ELSEVIER
DOI: 10.1016/j.jpowsour.2015.01.162
关键词
Proton exchange membrane electrolyzer; Bolt torque; Pressure distribution; Contact resistance; Performance measurement
资金
- Research Projects Unit of Nigde University [FEB2013/23]
The effect of bolt torque and contact resistance on the performance of Proton Exchange Membrane (PEM) Electrolyzers are investigated by a 50 cm(2) cell. The cell is designed and manufactured in house. The performance and contact resistance of the cell with three different gasket materials for demanding bolt torques are measured. The pressure distribution inside the cell is obtained by using pressure sensitive films. The pressure acting on the membrane electrode assembly (MEA) is calculated by analyzing and quantifying intensities of pressure film images. 3D plots of pressure distribution for predefined bolt torque values are obtained to understand the pressure distribution over the active area. The performance of the cell is enhanced when bolt torque is increased. However, beyond a value, relatively weak cell components such as diffusion layers are damaged and performance loss is observed due to the mass transfer limitations. The best efficiency is reached at 15 Nm bolt torque for Polytetrafiuoroethylene (PTFE) and Ethylene Propylene Diene Monomer (EPDM) gaskets. For silicon gasket best efficiency is reached at 15 Nm at lower current densities and at 10 Nm at higher current densities. Increasing clamping pressure is found to be developing more contact points between the interfaces and results in decrease in contact resistance inside the cell. (C) 2015 Elsevier B.V. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐