4.7 Article

Thermal and fire risk analysis of typical insulation material in a high elevation area: Influence of sidewalls, dimension and pressure

期刊

ENERGY CONVERSION AND MANAGEMENT
卷 88, 期 -, 页码 516-524

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.enconman.2014.08.026

关键词

Energy saving; Extruded polystyrene (XPS); Risk evaluation; Combustion characteristics; Downward flame spread; Heat transfer

资金

  1. National Basic Research Program of China (973 Program) [2012CB719702]
  2. Research Fund for the Doctoral Program of Higher Education [20113402110023]
  3. Key Technologies R&D Program of China during the 12th Five-Year Plan Period [2013BAJ01B05]
  4. Young Teacher Fund of Anhui University of Technology [QZ201109]
  5. State Key Laboratory of Fire Science [HZ2012-KF04, HZ2012-KF08]

向作者/读者索取更多资源

Small-scaled experiments and modeling are performed to investigate the downward flame spread over extruded polystyrene (XPS) slabs at different widths with and without sidewalls in a city (Lhasa, China) at high elevation. This study provides an understanding of the thermal characteristics and fire risk of XPS under the influence of various factors. It is found that the flame pulsation is more significant for wider samples. The average flame height (H) rises as the width increases. Compared to the results obtained without sidewalls, the flame pulsation is less considerable and H is higher for samples with sidewalls. When sidewalls are present, the average maximum flame temperature (T-max) increases with the rise of sample width, and it is lower than that without sidewalls. T-max in the combustion zone besides the sidewalls is larger than that in the middle zone, while the reverse is true for samples without sidewall. The solid-phase temperature curve is comprised of three stages. The temperature growth rate is low during the melting stage. The duration of the melting stage without sidewalls is longer than that with sidewalls. This duration at a low elevation is shorter than that at the high elevation. The shorter duration of the melting stage corresponds to the higher temperature at which the melting stage occurs. A three dimensional downward flame spread model taking into account the effects of sample width, thickness, ambient pressure and sidewall is established. The predicted trends of V-f using the model agree well with the experimental results. The model could also predict XPS fire hazard. The thermal and risk analysis of XPS provides a guidance to fire safety design of energy saving system of buildings. (C) 2014 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据