4.7 Article

Validation of EnergyPlus thermal simulation of a double skin naturally and mechanically ventilated test cell

期刊

ENERGY AND BUILDINGS
卷 75, 期 -, 页码 511-522

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.enbuild.2014.02.043

关键词

Thermal simulation; Validation; Double skin facade; EnergyPlus; Natural ventilation; Passive house

资金

  1. Fundacao Calouste Gulbenkian [126724]

向作者/读者索取更多资源

This paper presents a thermal simulation validation study of the typical precision that a trained thermal simulation engineer can expect to obtain for the simulation of a room connected to a naturally ventilated double skin facade. The open source building thermal simulation tool EnergyPlus is used to predict air and surface temperatures in a free running weather exposed test cell. The validation approach used does not allow for fine tuning the simulation model by trial and error and includes a sensitivity analysis on the impact of different simulation options such as: number of thermal zones, ground heat transfer and accuracy of solar radiation data. The analysis of the results is consistent with the engineering application goal by focusing on standard indicators: average error, bias and difference between predicted and measured daily maximums. The results show good agreement between simulation and experiment, with an average simulation error in air and radiant temperature of 1.4 degrees C and an average daily maximum error of 2.5 C. (C) 2014 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据