4.7 Article

Experimental determination of fouling factor on plate heat exchangers in district heating system

期刊

ENERGY AND BUILDINGS
卷 50, 期 -, 页码 204-211

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.enbuild.2012.03.039

关键词

District heating; Domestic hot water; Plate heat exchanger; Fouling factor

资金

  1. Ministry of Science and Technological Development of Serbia

向作者/读者索取更多资源

This paper presents the results of experimental research on 8 plate heat exchangers. Their purpose is to heat water for radiator heating system and domestic hot water. Measurements were carried out in 4 substations in district heating system in Belgrade (Serbia). The main achievement of this research was that the fouling factors were determined experimentally, and the found values can be used further on in design of plate heat exchangers in district heating systems. (c) 2012 Elsevier B.V. All rights reserved.