4.7 Article

Measurements of household electricity and domestic hot water use in dwellings and the effect of different monitoring time resolution

期刊

ENERGY
卷 36, 期 5, 页码 2943-2951

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.energy.2011.02.037

关键词

Household electricity; Domestic hot water; Energy use; Monitoring

资金

  1. Swedish Energy Agency
  2. Swegon AB, Sweden

向作者/读者索取更多资源

The use of household electricity and domestic hot water has been measured for 72 apartments in an apartment building located in the south of Sweden. The measurements were carried out with samples every 6 s, a tenfold increase in resolution compared to available published data, during a measurement period of five days, in the winter season, including a weekend. The influence of the time resolution on the distribution of data was analysed by integrating the 6 s data to represent longer logging intervals. Extreme values, especially the high values, are shown to be reduced if the time interval is increased. The maximum household electric power was 50% higher at a 6 s resolution compared to 60 s and the corresponding difference for domestic hot water flow was 40%. Daily variations has to be considered for photovoltaic installations and solar thermal collectors, energy simulations of buildings need at least hourly data and all kind of power design in a building or its services benefits from much more resolved data. (C) 2011 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据