4.7 Article Proceedings Paper

Optimal lay-out and operation of combined heat & power (CHP) distributed generation systems

期刊

ENERGY
卷 34, 期 12, 页码 2175-2183

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.energy.2008.10.019

关键词

Distributed cogeneration; District heating; Microturbines; MILP

向作者/读者索取更多资源

The paper presents an optimization model of a distributed cogeneration system with a district heating network, applied to a real city centre situation. The distributed urban cogeneration system includes both a set of micro-gas turbines, located inside some public buildings, and a centralized cogeneration system based on a Internal Combustion Engine. The objective function adopted for the optimization is the Total Annual Cost for owning, maintaining and operating the whole system. To face the problem a Mixed Integer Linear Program (MILP) is defined and solved by a commercial software. Starting from the thermal and electrical demand of the buildings, the MILP model allows to define the possible installation of the centralized cogeneration ICE (internal Combustion Engine) and the number of microturbines in the different buildings, the optimal lay-out of the district heating network and the optimal operation strategy for the whole system as well. In particular the energy performance and global CO2 emissions are evaluated. (C) 2009 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据