4.5 Article

Red blood cell quantification microfluidic chip using polyelectrolytic gel electrodes

期刊

ELECTROPHORESIS
卷 30, 期 9, 页码 1464-1469

出版社

WILEY
DOI: 10.1002/elps.200800448

关键词

Hematoanalyzer; Microfluidic chip; Polyelectrolytic gel electrode; Red blood cells

资金

  1. MKE (Ministry of Knowledge Economy)
  2. ITRC (Information Technology Research Center)
  3. IITA (Institute of Information Technology Advancement) [IITA-2009-(1090-0902-0002)]
  4. Ministry of Education, Science and Technology (MEST) [M10536090001-05N3609-00110]
  5. Korea Science and Engineering Foundation (KOSEF)
  6. Korea government (MOST) [R11-2007-012-02002-0(2009)]
  7. Ministry of Public Safety & Security (MPSS), Republic of Korea [C1090-0902-0002] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)
  8. National Research Foundation of Korea [과06A1501, 2007-0056334, 2005-2001249] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

向作者/读者索取更多资源

This paper reports on a novel microfluidic chip with polyelectrolytic gel electrodes (PGEs) used to rapidly count the number of red blood cells (RBCs) in diluted whole blood. The proposed microdevice is based on the principle that the impedance across a microchannel between two PGEs varies sensitively as RBCs pass through it. The number and amplitude of impedance peaks provide the information about the number and size of RBCs, respectively. This system features a low-voltage dc detection method and non-contact condition between cells and metal electrodes. Major advantages include stable detection under varying cellular flow rate and position in the microchannel, little chance of cell damage due to high electric field gradient and no surface fouling of the metal electrodes. The performance of this PGEs-based system was evaluated in three steps. First, in order to observe the size-only dependence of the impedance signal, three different sizes of fluorescent microbeads (7.2, 10.0, and 15.0 mu m; Bangs laboratories, USA) were used in the experiment. Second, the cell counting performance was evaluated by using 7.2 mu m fluorescent microbeads, similar in size to RBCs, in various concentrations and comparing the results with an animal hematoanalyzer (MS 9-5; Melet schloesing laboratories, France). Finally, in human blood sample tests, intravenously collected whole blood was just diluted in a PBS without centrifuge or other pretreatments. The PGE-based system produced almost identical number of RBCs in over 800-fold diluted samples to the results from a commercialized human hematoanalyzer (HST-N402XE; Sysmex, Japan).

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据