4.1 Article

Variability of the Minimal Transmembrane Voltage Resulting in Detectable Membrane Electroporation

期刊

ELECTROMAGNETIC BIOLOGY AND MEDICINE
卷 27, 期 4, 页码 372-385

出版社

TAYLOR & FRANCIS INC
DOI: 10.1080/15368370802394644

关键词

Electroporation; Electropermeabilization; Transmembrane voltage; Transmembrane potential; Membrane curvature

资金

  1. Slovenian Research Agency

向作者/读者索取更多资源

We present a study of the variability of the minimal transmembrane voltage resulting in detectable electroporation of the plasma membrane of spherical and irregularly shaped CHO cells (we denote this voltage by ITVc). Electroporation was detected by monitoring the influx of Ca2+, and the transmembrane voltage was computed on a 3D finite-elements model of each cell constructed from its cross-section images. We found that ITVc was highly variable, particularly in irregularly shaped cells, where it ranged from 512-1028 mV. We show that this range is much too large to be an artifact due to numerical errors and experimental inaccuracies, implying that for cells of the same type and exposed to the same number of pulses with the same duration, the value of ITVc can differ considerably from one cell to another. We also observed that larger cells are in many cases characterized by a higher ITVc than a smaller one. This is in qualitative agreement with the reports that higher membrane curvature facilitates electroporation, but quantitative considerations suggest that the observed variability of ITVc cannot be attributed entirely to the differences in membrane curvature.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.1
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据