4.6 Review

Electrochemical diamond sensors for TNT detection in water

期刊

ELECTROCHIMICA ACTA
卷 54, 期 24, 页码 5688-5693

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.electacta.2009.05.013

关键词

Boron doped diamond; Electrochemical sensor; TNT detection; Square wave voltammetry; Sea water

向作者/读者索取更多资源

An electrochemically stabilized boron doped diamond electrode prepared by chemical vapour deposition (CVD) is used for electrochemical TNT sensing in aqueous solutions. Square wave voltammograms (SWVs) exhibit three highly resolved peaks at -0.47, -0.62 and -0.76 V vs. Ag-AgCl reference electrode, respectively. The current vs. TNT concentration plot shows a linear relationship with a same slope for the two first TNT peaks at mu g L-1 and mg L-1 concentration ranges. Detection and quantification limits of 10 and 25 mu g L-1, respectively, were obtained without any preconcentration step. Relative standard deviation (RSD) of less than 1 % measured over 10 runs has been found for the -0.47 V peak current showing the very high stability of the electrode without any significant fouling effect. An interference study with nitro aromatic compounds of the same family (nitro toluene and dinitrotoluene) has shown that the -0.47 V reduction peak enables TNT discrimination. Measurement of TNT in a natural medium (sea water without any purification step except filtering) has been also investigated. (C) 2009 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据