4.6 Article

Evaluation of embeddable potential sensor for corrosion monitoring in concrete structures

期刊

ELECTROCHIMICA ACTA
卷 53, 期 24, 页码 7248-7254

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.electacta.2008.04.078

关键词

reinforcement corrosion; corrosion monitoring; embeddable sensor; potential sensor

向作者/读者索取更多资源

Embeddable potential sensor based on MnO2 was assembled and characterised in concrete. The stability, reversibility, polarisability and impedance characteristics have been Studied with respect to known reference. The corrosion performance of reinforced steel with respect to MnO2 sensor was monitored by different electrochemical techniques. Reversibility of MnO2 sensor indicated that difference of +/- 5 mV between the forward and reverse scan indicates the better reversibility characteristics in concrete. The rebar potentials (E-R) of steel with respect to MnO2 are -315 and -525 mV for passive and active conditions of rebar in concrete. The corrosion current from potentiodynamic polarisation and R-ct from a.c. impedance technique clearly differentiated the behaviour of steel embedded in chloride contaminated concrete (active condition) from uncontaminated concrete (passive condition) with respect to MnO2 sensor. All these studies revealed that corrosion monitoring of steel in concrete using embedded MnO2 as a better potential sensor for steel in concrete. In addition it is easy to fabricate for amenable miniaturisation, varied configuration as demanded for corrosion monitoring in concrete structures. (c) 2008 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据